Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 3 Next »

Sensing type

Selects the type of ohmic sensing to be used in the operation

  • Disable

    No ohmic sensing will be used in the operation

    Sensing type display when set to Disable
  • Initial height sensing (IHS)

    One-dimensional ohmic search will be used for arc transfer/pierce/cut height compensation

    Sensing type display when set to Initial height sensing

  • Touch along path

    Description

    Sensing type display when set to Touch along path

Initial height sensing (IHS)

If Sensing type is selected accordingly, allows the user to define a one-dimensional ohmic search for arc transfer/pierce height/cut height compensation

  • All cuts

    One-dimensional ohmic search will be performed on all cuts in the operation

    Apply IHS display when set to All cuts
  • First cut of each feature

    One-dimensional ohmic search will be performed on the first cut of each single- and multi-cut (beveled holes etc.) feature

    Apply IHS display when set to First cut of each feature
  • First cut only

    One-dimensional ohmic search will only be performed on the first cut of a multi-cut feature(-s)

    Apply IHS display when set to First cut only

Touch along path

If Sensing type is selected accordingly, allows the user to define a sequence of one-dimensional ohmic searches along the path, distributed according to a predefined parameter set.

  • All cuts

    The sequence of one-dimensional ohmic searches will be applied to every Plasma Cut Path within a Multi-cut feature

Apply touch display when set to All cuts
  • First cut of each feature

    The sequence of one-dimensional ohmic searches will be applied only to the first Plasma Cut Path within a Multi-cut feature

    Apply touch display when set to First cut of each feature

Add an extra touch before the lead-in

  • Add an extra touch before lead-in

    An extra one-dimensional ohmic search will be performed before lead-in part of the Plasma Cut Path

Add an extra touch before lead-in display when activated

Touch mode

  • Fixed number (for Touch along path)

    The one-dimensional ohmic searches will be evenly distributed along the Plasma Cut Path(s) based on their defined number and the length of the path

    Touch mode display when set to Fixed number
  • Distance (for Touch along path)

    The one-dimensional ohmic searches will be evenly distributed along the Plasma Cut Path(-s) at the intervals defined by the distance value

    Touch mode display when set to Distance

Distance between touches

Distance between touches display when set to 10.00

Defines the interval along Plasma Cut Path for ohmic search distribution in Distance Touch mode

Number of touches

Number of touches display when set to 4

Defines the number of ohmic searches to be evenly distributed along the Plasma Cut Path in Fixed number Touch mode

Auto adjust

Auto adjust display when activated

Spreads the ohmic searches evenly, adjusting the total number based on the distance between touches defined in Distance Touch mode. Ignores the lead-in, lead-out and overlap

Align at start

Align at start display when activated

Forces the first ohmic search to be at the start of the Plasma Cut Path.

Align at end

Align at end display when inactive

Forces the last ohmic search to be at the end of the Plasma Cut Path.

Transition height

Transition height display when set to 60

Defines the ohmic search entry point in the incremental mode with respect to the target search point

Transition speed

Transition speed display when set to 50

Defines the speed of movement from the ohmic search entry point to ohmic search starting point

Touch search height

Touch search height display when set to 50

Defines the ohmic search starting point in the incremental mode with respect to the target search point

Touch speed

Touch speed display when set to 20

Defines the speed of movement from the ohmic search starting point to ohmic search target point

Touch direction

Defines the direction of the ohmic search based on the option selected

  • Normal to surface

    Ohmic search direction is normal to the surface at path point; torch orientation is also normal to the surface at path point

    Touch direction display when set as Normal to surface
  • Along feature orientation

    Ohmic search direction follows the best approximation of tube/hole/code/edge axis direction; torch orientation is normal to the surface at path point

    Touch direction display when set as Along feature orientation
  • Along selected vector

    Ohmic search direction is defined by selecting a vector/planar surface (normal to the surface), or a set of unit vectors; torch orientation is normal to the surface at path point

    Touch direction display when set as Along selection
  • No labels