Problem

Issue

The operations in Robotmaster are not in the proper order and the robot goes back to home in between operationoperations.

...

...

This situation happens when you occurs when the operations in Mastercam have different NC file names for different operations.
When this is the case, Robotmaster will group the operations that have the same NC names and treat them as independent programs.


In the following example you can see that in Mastercam , that operations 1 and 5 are named AAA, operations 2 and 4 are named BBB and operation 3 is named CCC.
In Robotmaster, the operations will be grouped and ordered by NC name by in alphabetical order.Image RemovedImage Removed

...

Solution

...

...

Modify the NC name according to the operation order that you

...

would like to

...

see in Robotmaster.

If you want Robotmaster to follow the Mastercam operation order,

...

make sure all

...

operations

...

have the same NC program name

...

.

Also see How to rename a program in Mastercam (NC)